15.11.2006 Retsch GmbH 9 Doc. Nr. D 98.725.9998
Emissions
Noise characteristic values of RS200:
Noise measurement according to DIN 45635-31-01-KL3
The noise characteristic values are influenced mainly by the
machine speed, material to be milled and the milling set.
Workplace-related emission value L
pAeq
= up to 84 dB(A)
Noise power level L
WA
= 99 dB(A)
Conditions of measurement:
Milling set : 250 ml steel with ring (90/125) and Puk (65)
Milling material : 100g cement clinker, grain size <2mm,
6 milling aid tablets C20
Speed : 1450 min-1
Noise level measuring instrument: Brüel & Kjaer 2237 Controller
Materials and analyses of milling tools
See: www.retsch.com/english/docs/grinding_tools.pdf
Systems of protection
IP40
Protective equipment
The RS200 is fitted with an automatic lid shutting device which
prevents the machine being started in an unsafe condition. The
machine can be started only with the lid closed.
The lid can be opened only when the machine is at a standstill.
Mode of operation
S1
Operation with constant load, the duration of which is sufficient for the
thermal steady state condition to be reached (DIN VDE 0530 T1)
Machine dimensions
Height: up to approx. 1220 mm / width: 820 mm / depth: up to
approx. 780 mm
Weight : RS 200 net approx. 210 kg
Required floor space
Height (open hood): 1900 mm / width: 820 mm /
depth: 780 mm;
A safety distance of 100 mm on the rear side is necessary so that
the main switch can be operated.