Assembling and using the cyclone
29
Pos: 12.1 /00005 Ü berschriften/ 1. Überschriften/ 1 Verwendung von Zyklon und Bodenplatte für Weithalsflasc hen – SM30 0 @ 3\mod_127 9541116382_9. doc @ 20674 @ @ 1
7 Assembling and using the cyclone
Pos: 12.2 /00005 Ü berschriften/ 1.1 Überschrifte n/1.1 Überschrift en BDA/11 Z yklon Montage ( 2) @ 3\mod_1 27954115639 8_9.doc @ 20 683 @ @ 1
7.1 Cyclone assembly
Pos: 12.3 /00004 Warnhinweis e/V0014 VORSICHT Rotierende Me sser @ 2\ mod_12634800 51017_9.doc @ 18590 @ @ 1
Injuries to limbs
Rotating blade
– Can cause injury to hands and feet.
• Keep hands and feet away from the device openings
when the device is switched on.
• Pull the plug out before cleaning or retrofitting.
Pos: 12.4 /00004 Warnhinweis e/V0001 VORSICHT A/jointfilesconvert/1599383/bgetrennte Finger - Eingri ff in den dreh enden Rotor @ 2\mod_127 9183830134_9. doc @ 20580 @ @ 1
Risk of injury to fingers
Reaching into the turning rotor
– Unintended reaching into the grinding area and the turning
rotor.
• Never connect the device to the mains without the
discharge flange.
• Only operate the device with discharge flange.
Pos: 12.5 /00010 Bedienungsa nleitungen Ka pitelsammlunge n/SM300 Zyklon ( 2011)/0001 Z ySM Kapitel Z yklon Montage/0 201 ZySM Mo dul Montage Zyklo n @ 2\mod _127918682853 3_9.doc @ 20 601 @ 3 @ 1
Fig. 16: Removing the discharge flange
• Disconnect the device from the mains.
• Loosen the screw (A1).
• Pull off the discharge flange (AV).
Comments to this Manuals