Operating the machine
32
Pos: 9.43 /0020 Üb erschriften/1 .1 Überschriften/ 1.1 Überschrif ten BDA/11 Man ueller Betrieb @ 7\mod_1 38677310160 3_9.docx @ 53507 @ 3 @ 1
5.13 Manual operation
Pos: 9.44 /0005 RET SCH Bedi enungsanleitung en Kapitelsam mlungen/AS200J et/0007 AS20 0Jet Bedienung/ AS200jet Mo dul Manueller Betr ieb @ 7\ mod_1386774 886925_9.doc x @ 53540 @ 233 333 @ 1
5.13.1 Sieve duration
00:01 to 99:59 (minutes : seconds)
5.13.2 Speed
5 to 55 revolutions per minute (10 revolutions per minute “Open Mesh”
5.13.3 Vacuum
You can adjust the vacuum when the automatic suction force adjustment has been
connected. (Pa; mbar; psi)
5.13.4 Open Mesh
Display whether Open Mesh is active: YES / NO
The air nozzle is moved two steps in the direction of rotation and then one step
back. The speed is fixed when Open Mesh is switched on to 10 revolutions per
minute.
Open Mesh switched on
Open Mesh switched off
5.13.5 Save parameters
All previously set parameters such as sieve duration, speed, vacuum (only with
connected automatic suction force adjustment) and Open Mesh can be saved in a
memory here.
Set the desired parameters.
By turning the operating button (F), switch to the menu point Save
parameters.
Press the operating button (F).
The Save parameters menu opens and the dark line cursor is on Program.
Press the operating button (F) to select a program memory location or Quick
Start.
By turning the operating button (F) switch to the desired memory location.
Press the operating button (F) to exit the memory location selection.
Select either
Save to save settings or
back to cancel without saving.
5.13.6 Suction apparatus
Fig.
3
: Connector (electrical connection for the external suction apparatus)
Using the suction apparatus menu point, you can switch on the vacuum cleaner
connected to the connector (P) independently of sieving.
By turning the operating button (F) switch to the suction apparatus menu
point.